Wavetronix SmartSensor Advance Extended Range (SS-200E) - Use Manual do Utilizador Página 82

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 148
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 81
CHAPTER 7  CHANNELS-ALERTS-ZONES 81
Normal channels consist of four alerts, each containing four zones. A normal channels
output is a logical combination of the channels alert, zone, delay and extend settings (see
Delay and Extend sections under Latched Channels). e normal channels output becomes
active when the associated alert and zone logic, the channel delay or the channel extend are
satised.
Each enabled normal channel must have at least one enabled alert. If you attempt to save an
invalid channel conguration, the following message is displayed (see Figure 7.13).
Figure 7.13 – Invalid Channel Configuration
Latched Channel
Latched channels consist of two alerts (ON and OFF), each containing up to four zones (see
Figure 7.14). A latched channel, by denition, has exactly two enabled alerts that cannot be
disabled.
Channel 1
ON
Alert
OFF
Alert
Zone
1
Zone
2
Zone
3
Zone
4
Zone
1
Zone
2
Zone
3
Zone
4
Figure 7.14 – Latched Channel Hierarchy
Latched channels dier from normal channels in that the channel output remains in a given
state until a contradictory alert is exclusively activated, or a maximum latch time has ex-
pired (see Figure 7.15).