Wavetronix Click 112 (detector rack card) (CLK-112) - Quick-r Manual do Utilizador Página 3

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 4
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 2
5
Configuration option 2: front panel menu
e front panel menu allows you to congure input mapping and baud rates. It can also reset the device to
factory defaults, and is the only place on the device to access the autobaud function.
Menu and conguration options are displayed on the Level 1 and Level 2 LEDs on the faceplate. Navigate
through the menu using the mode switch:
1 Press and hold the mode switch to enter Menu mode. e Level 1 LEDs will start to light up to indicate
that the device is cycling through all menu options.
2 When the LEDs light up in the way that indicates the menu option you want (see the gure below),
release the mode switch.
3 Quickly press and release the mode switch to select the current menu option. e Level 2 LEDs will
light up to let you congure the options for the selected menu option.
4 Press and hold the mode switch to cycle through available values for the selected menu option. e
Level 2 LEDs display the currently selected value.
5 Press and release the mode switch to accept the displayed value. e device will exit the menu.
Note. If any of the DIP switches are turned on, that parameter will be in Hardware mode and the front
panel menu will only be able to display, not change, that setting.
See the gure to the right for how to use the LEDs to congure the parameter.
Channel Input Mapping
is function lets you map two (Click
112) or four (Click 114) of the input
data channels coming from the sensor to
the output channels on the device. e
outputs are assigned sequentially, so if you
select 13–14, then input 13 will be mapped
to channel 1, and 14 to channel 2.
Baud Rate for Bus 1 and Bus 2
is function lets you set the baud rate
for bus 1 and bus 2. e two buses can
be congured separately.
Autobaud
is function initiates an autobaud on the RS-485 bus you select. If the autobaud is successful, the LEDs will
display the baud rate found, using the same LED patterns used for the baud rate (see gure above). If it fails,
all four LEDs will ash, and then the device will exit the menu.
Reset to Default
is function will restore all conguration settings to factory defaults (even those not congured using the
front panel menu): baud rate, channel map, description eld, location eld and device ID.
Vista de página 2
1 2 3 4

Comentários a estes Manuais

Sem comentários